Domains · Physical AI
Leading autonomous systems teams
An autonomous system acts without a person checking each decision, so the evidence that it is safe enough is as much the product as the behaviour. Leading here means owning a safety argument, a bounded operating domain, a long tail of rare situations and the trust of regulators and the public.
See the 22 roadmap steps this changes ↓What is different here
- 01
The safety case is a deliverable
You are not done when the system performs. You are done when you can argue, with evidence, that the remaining risk is acceptable, and someone whose judgement does not depend on the schedule accepts the argument. That changes planning. Evidence has to be designed in from the first milestone, because it cannot be assembled in the last month.
Give the safety case a named owner and a reporting line that can delay a launch. Treat each release and each widening of the operating domain as a signed claim. At every review, ask which claims still lack evidence. When delivery pressure and the safety argument conflict, people watch what you do, and that becomes the culture.
- guideUL 4600: Standard for Safety for the Evaluation of Autonomous Products (opens in a new tab)Philip Koopman
- guideGuidance on the Safety Assurance of Autonomous Systems in Complex Environments (SACE) (opens in a new tab)Centre for Assuring Autonomy, University of York
- guideGoal Structuring Notation (GSN): standard and guidance (opens in a new tab)Safety-Critical Systems Club
- 02
The long tail sets the schedule
Common situations work early and make the remaining work look small. What remains is an open-ended supply of rare situations: odd objects, unusual behaviour by other people, sensor conditions nobody listed. Each is unlikely on a given day and, across a fleet, certain to occur. Test distance alone cannot show safety at the level the public expects, so a date extrapolated from the demo is fiction.
Plan around discovery. Track how often testing reveals a kind of situation you had not seen before, and treat a rate that has stopped falling as a schedule fact. Fund the triage of surprises as a standing function. Design the system to recognise that it is unsure and fall back to a safe state.
- 03
The operating domain is a business decision
The operational design domain states where, when and in what conditions the system is designed to work: which roads or airspace, what weather, what speeds, what time of day. A narrow domain reaches service sooner and with a simpler safety argument. A wide one reaches more customers. That trade is the central product decision, and you make it jointly with product, safety and operations.
Write the domain down precisely enough to test against. Make sure the system can detect that it is leaving the domain and reach a safe stop. Then guard the boundary. Sales, partners and your own optimism will push to add one more condition, and each addition needs its own evidence before it ships.
- 04
Permission to operate can be withdrawn
You operate with the consent of regulators and of the people who share the road, the sky or the site with your system. Neither group reads your metrics. They judge by incidents, by how candid you were afterwards and by whether your claims held up. One serious event can ground a fleet, and a misleading account of it does more damage than the event itself.
Build the relationship before you need it. Know your reporting duties in each jurisdiction and who files. Brief regulators on changes before they hear about them elsewhere. Prepare the incident statement process in advance. Never let a public claim outrun the evidence in the safety case.
- guideStanding General Order on Crash Reporting (opens in a new tab)National Highway Traffic Safety Administration
- guideAutomated vehicles: joint review and reports (opens in a new tab)Law Commission of England and Wales and Scottish Law Commission
- guideSpecific Operations Risk Assessment (SORA) (opens in a new tab)European Union Aviation Safety Agency
- 05
The human fallback is a designed role
Most autonomous systems still lean on people: a safety operator on board, a remote assistant, a field team that recovers stuck units. It is tempting to count that person as the safety net. But watching a system that almost always works is a task humans do badly, and an operator who is bored, overloaded or poorly trained will not intervene in time.
Run oversight as an operation you own. Set training, shift length, workload per person and what the operator may and may not do. Measure reaction, not presence. Give operators a direct line to engineering and act on what they report. If the safety case depends on a human, it needs evidence about how that human really performs.
- 06
Progress measures that get gamed
The easy numbers are distance covered and how often a human had to take over. Both mislead. Distance on easy routes proves little. Takeover counts fall when routes get simpler or when operators are nudged to wait longer, which makes the number better and the system more dangerous.
Use several measures and never make one a target. Combine leading indicators, such as near misses, rule violations and margin to other road users, with outcomes. Break results down by scenario and condition. For each number, ask how it could improve without the system getting safer, then check whether that is happening.
On the roadmaps
These steps change when the team works in autonomous systems. Set it as your field and every roadmap highlights them.
AI and Physical AI Team Leader
open with this as your field →- Safety cases and hazard analysis
Give the safety case an owner whose reporting line does not run through the delivery schedule, and require their sign-off for every widening of where the system may operate.
- Testing in the field
Testing in public is itself an operation that needs a safety argument: operator training, shift limits, routes and a written rule for when testing stops.
- Human oversight and teleoperation
Decide whether the remote human advises or controls, what the system does when the link drops and how many units one person may supervise. Each answer is a safety claim that needs evidence.
- Roadmaps under research uncertainty
Plan by operating domain: which conditions you add, in what order and what evidence each needs. A date for working everywhere is not a commitment you can keep.
- Evaluation as the product spec
Organise evaluation by scenario across the operating domain and weight by severity. An average over distance hides the rare cases that decide whether the system is safe.
- Monitoring and drift
Monitor for leaving the operating domain and for kinds of situation you have not seen, as well as model drift. Track near misses and hard stops as safety indicators.
- Incident response for model failures
Be able to halt the fleet in minutes, preserve data for investigators and notify the regulator inside the legal deadline. Rehearse all three before public operation.
- Fleet operations and over-the-air updates
A software update can invalidate safety evidence. Agree in advance which changes need which re-validation, or frequent releases will outrun the safety case.
- Regulation and standards awareness
Permission is granted per jurisdiction and can be withdrawn. Name an owner for each regulator relationship and bring evidence before you are asked for it.
- Setting expectations with product
Product will want a wider operating domain. Agree that each expansion is gated by evidence, and give product the list of what each new condition requires.
- Communicating capability honestly
State the operating domain every time you describe capability. The public hears words like driverless or fully autonomous as a claim with no limits.
Reliability and SRE Leader
open with this as your field →- Severity levels
Define severity by actual and potential harm to people, and include near misses. An event with no damage can be the most serious thing that happened this quarter.
- Blameless learning reviews
Reviews may be read by regulators, insurers and courts. Agree with counsel how to keep them candid and complete, and do not let legal caution stop the learning.
- Change management and safe deploys
Gradual rollout still applies, but the first stages are replay and simulation against known hard scenarios, then a small supervised part of the fleet.
Senior Engineer to Engineering Manager
open with this as your field →- Planning and estimates
Estimate the validation as well as the build. For a change to driving or flight behaviour, gathering the evidence can take longer than writing the change.
- Quality without reviewing it all
Done includes the evidence. A feature that works but has no place in the safety argument is unfinished, and your definition of done should say so.
Engineering Manager to Director
open with this as your field →- Team boundaries and ownership
Keep safety assurance independent of the teams whose work it assesses, yet close enough to see that work daily. A safety group that only audits at the end finds problems too late.
- Engineering metrics, used with care
Takeover and intervention rates depend on routes and operator caution. Use them to find problems, never as a target, or people will learn to intervene less.
Director to VP of Engineering
open with this as your field →- Crisis leadership
A serious incident brings police, regulators and press within hours. Prepare the response plan, the spokesperson and data preservation before the first public operation.
- Working with the board
The board is accepting safety risk as well as schedule risk. Report safety indicators and open gaps in the safety case next to progress, in the same pack.
Startup CTO
open with this as your field →- Explaining engineering to the board
Investors compare companies on demos and distance covered. Report the operating domain, the evidence behind it and what would stop operations, so nobody funds a date you cannot keep.
Hardware and Embedded Engineering Manager
open with this as your field →- Functional safety for leaders
Functional safety covers malfunctions. Autonomy also needs an argument for the case where nothing is broken and the system still misreads the situation.